Kenmore 796 model steam dryer error codes
These error code explanations can help you diagnose a problem with your Kenmore steam dryer with a model number beginning with 796. For repair how-to help, visit the PartsDirect repair help section, which includes repair help for dryers, other major appliances, lawn and garden equipment, garage door openers, vacuum cleaners and more. Search for your model number to find a complete list of replacement parts for your dryer.
Exhaust thermistor failure
Unplug the dryer and check the exhaust thermistor wiring. Reconnect any loose wires or replace the wire harness if damaged. Check the resistance of the exhaust thermistor using a multimeter. You should measure about 10,000 ohms at room temperature. If not then replace the thermistor because it's defective. Replace the main control board if the exhaust thermistor and wiring are okay.
Door switch error
Check the operation of the door switch using the diagnostic test mode, which is explained in the tech sheet that's typically stored in the console of the dryer. Replace the door switch if it doesn't work.
Power supply error
The power cord on the back of the electric dryer isn't correctly connected. Unplug the dryer and connect the power cord according to the installation instructions.
Steam generator thermistor failure
Unplug the dryer and check the wire harness connections between the steam generator and the main control board. Reconnect any loose wires or replace the wire harness if damaged. If the wire connections are okay, replace the steam generator because it houses the steam generator thermistor. The steam generator thermistor isn't sold as a separate component.
Steam feeder is dry
Refill the steam feeder with water.
Most common symptoms to help you fix your dryers
Choose a symptom to see related dryer repairs.
Main causes: bad gas valve coils, broken heating element, tripped safety thermostat or fuse, bad operating thermostat, c…
Main causes: bad timer or electronic control board, door switch failure…
Main causes: lack of electrical power, bad power cord, wiring failure, bad control board, blown thermal fuse, bad door s…
Main causes: clogged exhaust vent, bad motor relay, loose dryer door catch, bad door switch, control system failure, fau…
Main causes: damaged door strike, worn door catch…
Main causes: bad drum support roller, damaged idler pulley, broken blower fan blade, worn drum glide bearing, bad drive …
Main causes: clogged exhaust system, heating system failure, deposits on moisture sensor, control system failure…
Main causes: door switch failure, lack of power, broken belt, blown thermal fuse, bad drive motor, control system failur…
Most common repair guides to help fix your dryers
These step-by-step repair guides will help you safely fix what’s broken on your dryer.
How to replace a thermal fuse in an electric dryer
When the air in the dryer overheats—usually because the vent is clogged—the thermal fuse blows, stopping the dryer. You …
How to install a thermal cut-off fuse kit in an electric dryer
The thermal cut-off fuse shuts off the heat if the dryer overheats when the high-limit thermostat fails. Install a ther…
How to replace a dryer door switch
The dryer won't start if the door switch isn't working correctly. You can install a replacement dryer door switch in les…
Effective articles & videos to help repair your dryers
Use the advice and tips in these articles and videos to get the most out of your dryer.
Get expert tips on using your dryer efficiently to save energy.…
Learn about all the convenient features on our Sears PartsDirect website that make your parts purchases easier.…
Get answers to frequently asked questions about Sears and Sears PartsDirect.…