How to replace a refrigerator water valve
This repair guide gives easy-to-follow instructions for replacing the water inlet valve on a refrigerator. The water valve controls the flow of water to the ice maker and water dispenser. If the water inlet valve fails, it won't open to allow water flow, or it lets water flow constantly even when the refrigerator is unplugged. If the water inlet valve is defective, replace it with a manufacturer-approved fridge part.
These instructions work for replacing the water inlet valve on Kenmore, Whirlpool, GE, LG, Samsung, KitchenAid, Maytag, Amana, Frigidaire, Electrolux and Haier refrigerators.
Replacing a refrigerator water inlet valve video.
Instructions
- 01.
Shut off the power and water supply
Safely store any food that could deteriorate while the refrigerator is shut off. Then unplug the refrigerator or shut off the circuit breaker for the refrigerator.
Close the water supply cut-off valve for the ice maker. The valve is often on the wall behind the refrigerator, but could be attached to a water pipe under the kitchen sink or in the basement below the fridge.
- 02.
Disconnect the water supply line
Pull the refrigerator away from the wall far enough so you can access the water line connection and work on the back of the refrigerator. Place a towel under the water valve assembly to catch water. Loosen the nut on the supply water line until the water line is free.
Tip: If needed, refer to the owner's manual for additional guidance with disconnecting the water line.PHOTO: Disconnect the water supply line.
- 03.
Remove the back panel
Use a Phillips screwdriver to remove the screws that secure the lower service panel on the back of the refrigerator. Remove the panel.
PHOTO: Remove the back panel screws.
PHOTO: Remove the back panel.
- 04.
Remove the mounting bracket
Remove the screw that secures the mounting bracket to the frame of the refrigerator.
PHOTO: Remove the mounting screw.
PHOTO: Release the bracket.
- 05.
Remove the valve assembly
Press the back of the locking tab on the wire harness to release the tab. Pull the wire harness plug off the valve.
Remove the black plastic C-clip from the collar of the water line connection. Push the collar in and simultaneously pull the water line from the inlet water valve assembly.
PHOTO: Remove the wires.
PHOTO: Release the C-clip.
PHOTO: Remove the water line.
- 06.
Install the new valve assembly
Push the water line into the fitting on the new water valve assembly. Reinstall the C-clip on the collar of the fitting.
Tip: Push the water line as far as possible into the fitting. Tug on the water line to make sure it’s seated properly. - 07.
Reconnect the wire harness
Push the wire harness plug back onto the spades of the water valve assembly. Push the plug in until the locking tabs snap into place.
- 08.
Mount the new valve
Position the bracket of the new valve assembly so that the mounting holes line up. Reinstall the mounting screw and tighten firmly.
- 09.
Reinstall the service panel
Position the lower service panel on the back of the refrigerator so that the screw holes line up. Insert the screws and tighten firmly.
- 10.
Reconnect the water supply line
Wrap a small amount of pipe thread tape around the water supply line fitting on the back of the water valve. Fit the water line into the water valve assembly and tighten the compression nut firmly.
Open the water supply cut-off valve. If the fitting leaks, tighten the compression nut and check again.
- 11.
Restore electrical power
Plug in the refrigerator or turn on the house circuit breaker to restore power.
Most common symptoms to help you fix your refrigerators
Choose a symptom to see related refrigerator repairs.
Main causes: blocked vents, defrost system problems, evaporator fan failure, dirty condenser coils, bad sensors, condens…
Main causes: damaged door seal, faulty defrost sensor or bi-metal thermostat, broken defrost heater, bad defrost timer o…
Main causes: jammed ice cubes, broken ice maker assembly, dirty water filter, kinked water line, bad water valve, freeze…
Main causes: control board or cold control failure, broken compressor start relay, compressor motor failure, defrost tim…
Main causes: leaky door gasket, defrost system failure, evaporator fan not running, dirty condenser coils, condenser fan…
Main causes: blocked air vents, compressor problems, condenser or evaporator fan not working, control system failure, se…
Main causes: water valve leaking, frozen or broken defrost drain tube, overflowing drain pan, cracked water system tubin…
Things to do: clean condenser coils, replace the water filter, clean the interior, adjust doors to prevent air leaks, cl…
Most common repair guides to help fix your refrigerators
These step-by-step repair guides will help you safely fix what’s broken on your refrigerator.
How to replace a refrigerator water valve
Replace the water valve that feeds water to the ice maker and water dispenser if it no longer controls the flow of water…
How to clean refrigerator condenser coils
Help your refrigerator run more efficiently by cleaning the condenser coils. It's easy and takes just a few minutes.…
How to replace a refrigerator temperature control board
If the temperature in your refrigerator doesn't match the temperature you set, the problem could be the temperature cont…
Effective articles & videos to help repair your refrigerators
Use the advice and tips in these articles and videos to get the most out of your refrigerator.
No matter what style Maytag refrigerator you have, we can walk you through replacing the water filter.…
Get answers to frequently asked questions about Sears and Sears PartsDirect.…
If your refrigerator's ice maker isn't producing as much ice as it should, or water is flowing poorly from the dispenser…