Official ICP air handler parts

ICP air handlers have earned a reputation for reliability over the years. Dependable motors and sturdy components go into every ICP air handler. After years of use, parts can wear down and break in your air handler. When your ICP air handler isn't moving air as it should, find the repair parts you need to fix the problem at Sears PartsDirect.

Frequently bought ICP parts

Parts you might be looking for

Icp Furnace Heat Exchanger 320723-751

Icp Furnace Heat Exchanger

Part #320723-751
In Stock
$251.13
5% OFF Phone Price : $263.13
Minus Item
Qty
Plus Item
Furnace Electronic Control Board (replaces 1172551) 1172809

Furnace Electronic Control Board (replaces 1172551)

Part #1172809
Back Order
$339.63
$12.00 OFF Phone Price : $351.63
Minus Item
Qty
Plus Item
Central Air Conditioner Condenser Fan Motor (replaces 1172709) 1185924

Central Air Conditioner Condenser Fan Motor (replaces 1172709)

Part #1185924
In Stock
$342.43
$12.00 OFF Phone Price : $354.43
Minus Item
Qty
Plus Item

Popular maintenance items for Air Handlers

Parts you might be looking for

Appliance Screw WP489069

Appliance Screw

Part #WP489069
In Stock
$4.39
19% OFF Phone Price : $5.39
Minus Item
Qty
Plus Item
Furnace Fan Control Relay 1170063

Furnace Fan Control Relay

Part #1170063
In Stock
$217.41
5% OFF Phone Price : $229.41
Minus Item
Qty
Plus Item
Appliance Cable Tie WPW10339879

Appliance Cable Tie

Part #WPW10339879
In Stock
$4.37
19% OFF Phone Price : $5.37
Minus Item
Qty
Plus Item

What to do when your ICP air handler won't move air

  • Check the air filter. A clogged air filter won't let any air go through the air handler. Replace the air filter if it's dirty.
  • Check the vent grill. A blocked or dirty return air vent grill can inhibit air flow through the air handler. Move any items stacked in front of the return vent grill. Clean the vent grill if it's dirty.
  • Check the house circuit breaker. If the air handler blower motor isn't running at all, reset the house circuit breaker for the hair handler. If the motor still doesn't run, you'll likely need to have a service technician examine and repair the air handler.

How to troubleshoot your ICP air handler when it won't run

Check for power and reset the house circuit breaker for the air handler if it's tripped. If the air handler is getting power, check the thermostat settings and adjust the settings if necessary.

Check for water dripping from beneath the air handler. If water if dripping from the bottom of the air handler, then the condensate drain hose is likely clogged. A switch in the air handler shuts off the unit when the drain hose clogs and water backs up into the evaporator. Unclog the drain hose and the switch should reset so the air handler will run.

If these tips don't help, then a bad blower motor or a failed control board could be preventing the air handler from running.