Can’t find your part?   Contact us:   +1-309-603-4777
Open Hamburger Menu
Sears Parts Direct
Tips to find your model number
Cart
Orders
Your models

Keep track of the models you own in your profile

Sign in or Register to view or add models

Schedule a repair
Kenmore Elite Room air conditioners

Official Kenmore Elite room air conditioner parts

Sears PartsDirect is a leading supplier of repair parts for Kenmore Elite room air conditioners. Kenmore Elite room air conditioners have the features you need to keep a room cool and comfortable during hot summer months. When your Kenmore Elite room air conditioners isn't cooling as it should, find the replacement parts you need to fix the problem at Sears PartsDirect.

Frequently bought Kenmore Elite parts

Parts you might be looking for

Genuine Kenmore Refrigerator Water Filter 9081

Kenmore Refrigerator Water Filter (replaces 9930, W10743248)

Part #9081

Replaced by #9081

Info Icon
Manufacturer substitution
This part replaces 9081. Substitute parts can look different from the original.
Back Order
$54.98
Minus Item
Qty
Plus Item
Kenmore Refrigerator Water Filter 9690 (agf80300801)(replaces Adq36006102) ADQ36006114

Kenmore Refrigerator Water Filter 9690 (adq36006114)

Part #ADQ36006114

Replaced by #AGF80300801

Info Icon
Manufacturer substitution
This part replaces ADQ36006114. Substitute parts can look different from the original.
In Stock
$81.95
Minus Item
Qty
Plus Item
Kenmore Refrigerator Water Filter 9083

Kenmore Refrigerator Water Filter (replaces 9020, 9020b, 9030 And 9030b)

Part #9083

Replaced by #9083

Info Icon
Manufacturer substitution
This part replaces 9083. Substitute parts can look different from the original.
Back Order
$54.98
Minus Item
Qty
Plus Item
Kenmore Refrigerator Water Filter 9085

Kenmore Refrigerator Water Filter (9085) (replaces Kedr5rxd1, 2203221, 2203980, 2255520, 4392922, 8212491, 9010, 9902 And 9908)

Part #9085

Replaced by #9085

Info Icon
Manufacturer substitution
This part replaces 9085. Substitute parts can look different from the original.
In Stock
$54.98
Minus Item
Qty
Plus Item

Popular maintenance items for Room Air Conditioners

Parts you might be looking for

Appliance Silicone Sealant (replaces 279368) WP279368

Appliance Silicone Sealant (replaces 279368)

Part #WP279368
In Stock
$42.72
12% OFF Phone Price : $48.72
Minus Item
Qty
Plus Item
Dryer Screw (replaces 3387230) WP3387230

Dryer Screw (replaces 3387230)

Part #WP3387230
In Stock
$4.39
19% OFF Phone Price : $5.39
Minus Item
Qty
Plus Item
Dryer Screw WPW10109200

Dryer Screw

Part #WPW10109200
In Stock
$4.39
19% OFF Phone Price : $5.39
Minus Item
Qty
Plus Item
Light Switch WR23X10725

Refrigerator Light Switch (replaces Wr23x10143, Wr23x27351)

Part #WR23X10725

Replaced by #WR23X37285

Info Icon
Manufacturer substitution
This part replaces WR23X10725. Substitute parts can look different from the original.
In Stock
$63.20
Minus Item
Qty
Plus Item

Top replacement parts for Kenmore Elite room air conditioners

  • User interface control board. The user interface control board is a circuit board with selection buttons and display components, which is mounted on the control panel of the air conditioner. The user interface control board sends signals to the electronic control board to communicate the window air conditioner’s settings.
  • Thermistor. The thermistor is a temperature sensor in the window air conditioner that sends information to the electronic control board.
  • Compressor. The compressor receives low-pressure refrigerant gas from the evaporator and rotates to compress that refrigerant to a high-pressure gas that moves through the condenser. The refrigerant gets hot when compressed by the compressor pump. The condenser is a heat exchanger that removes heat from the refrigerant gas and condenses it into a high-pressure liquid refrigerant. The high-pressure liquid refrigerant flows through the expansion device and into the evaporator that's at low pressure. The high-pressure refrigerant expands and evaporates. It absorbs the latent heat of vaporization as it changes from a liquid to a gas, which causes the cooling action in the evaporator. The refrigerant flows through the evaporator and back to the compressor where the cycles starts over.
  • Evaporator fan. The evaporator fan is mounted behind the evaporator assembly. It moves air across the evaporator fins and into the room for cooling.
  • Electronic control board. The electronic control board controls the major electro-mechanical components in the window air conditioner. The electronic control board receives input from temperature sensors to monitor the temperatures inside the room and at the evaporator. With this information, the electronic control board manages the on/off cycling of the compressor to cool the room to the set temperature. The electronic control board activates the compressor and fans when it senses that the room temperature exceeds the set temperature.
  • Condenser fan. The condenser fan moves air across the condenser to enhance the cooling process of the hot, compressed refrigerant that flows through the condenser.

How to fix your Kenmore Elite room air conditioner when water leaks inside your house

If water is leaking into the room from the air conditioner, adjust the air conditioner so the back of the unit is slightly lower than the front, to allow the condensate water to drain outdoors. Level the air conditioner according to the guidelines in the installation manual.

The air conditioner can also leak into the room if gaps around the window let warm, moist into the room, where it can condense on the front of the air conditioner. Seal air leaks in the cabinet or around the window opening.