Maytag Neptune dryer error codes
These explanations for Maytag Neptune dryer error codes can help troubleshoot problems in your Maytag dryer.
Maytag Neptune dryer error codes appear on the display when the control detects a part failure. Follow the advice in the chart below to find the cause of the failure then order the replacement part. Search for your model number to find a complete list of replacement parts for your dryer.
For repair how-to help, visit the PartsDirect repair help section, which includes repair help for dryers, other major appliances, lawn and garden equipment, garage door openers, vacuum cleaners and more.
Thermistor (temperature sensor) is defective
Clean the lint filter and exhaust duct system, because high temperature due to blocked exhaust air flow is sensed as a faulty thermistor. If the exhaust vent system is clear, replace the thermistor.
Not heating
Unplug the dryer and check the heating system components. For an electric dryer, check the house circuit breakers to see if one has tripped. For a gas dryer, make sure that the gas supply cut-off valve is fully open.
Door switch failure
Unplug the dryer and lift the top panel to access the door switch. Reconnect any loose wires. Replace the door switch wire harness if damaged. If the wire harness is okay, replace the door switch.
Drive motor relay failure on the machine control board
Unplug the dryer and open the control panel to access the machine control board. Reconnect any loose wires on the machine control board. Replace the main wire harness if damaged. If the wire harness connections are okay, replace the machine control board.
Stuck key on the control panel
Press each key firmly to free up the stuck key. Replace the control panel if the key remains stuck.
Most common symptoms to help you fix your dryers
Choose a symptom to see related dryer repairs.
Main causes: bad gas valve coils, broken heating element, tripped safety thermostat or fuse, bad operating thermostat, c…
Main causes: bad timer or electronic control board, door switch failure…
Main causes: lack of electrical power, bad power cord, wiring failure, bad control board, blown thermal fuse, bad door s…
Main causes: clogged exhaust vent, bad motor relay, loose dryer door catch, bad door switch, control system failure, fau…
Main causes: damaged door strike, worn door catch…
Main causes: bad drum support roller, damaged idler pulley, broken blower fan blade, worn drum glide bearing, bad drive …
Main causes: clogged exhaust system, heating system failure, deposits on moisture sensor, control system failure…
Main causes: door switch failure, lack of power, broken belt, blown thermal fuse, bad drive motor, control system failur…
Most common repair guides to help fix your dryers
These step-by-step repair guides will help you safely fix what’s broken on your dryer.
How to replace a thermal fuse in an electric dryer
When the air in the dryer overheats—usually because the vent is clogged—the thermal fuse blows, stopping the dryer. You …
How to install a thermal cut-off fuse kit in an electric dryer
The thermal cut-off fuse shuts off the heat if the dryer overheats when the high-limit thermostat fails. Install a ther…
How to replace a dryer door switch
The dryer won't start if the door switch isn't working correctly. You can install a replacement dryer door switch in les…
Effective articles & videos to help repair your dryers
Use the advice and tips in these articles and videos to get the most out of your dryer.
Get expert tips on using your dryer efficiently to save energy.…
Learn about all the convenient features on our Sears PartsDirect website that make your parts purchases easier.…
Get answers to frequently asked questions about Sears and Sears PartsDirect.…