GE water softener error codes
These error code explanations can help you diagnose a problem with your GE water softener. For repair how-to help, visit the PartsDirect repair help section, which includes repair help for water softeners, other major appliances, lawn and garden equipment, garage door openers, vacuum cleaners and more. Search for your model number to find a complete list of replacement parts for your water softener.
Valve motor failure
If the valve motor doesn't run, unplug the water softener and check the valve motor wire harness for damage or a loose connection. Reconnect the valve motor wire harness if disconnected. Replace the valve motor wire harness if damaged. If the motor runs but the rotor valve doesn't move, the problem could be a defective motor or a locked-up rotor valve. Replace the valve motor if defective. Replace the rotor valve if it's locked up. If the motor runs and spins the rotor valve constantly, the position switch may be defective. Replace the position switch if it doesn't detect the rotor valve position.
Defective timer
Unplug the water softener for 1 minute and then reconnect power to reset the timer. If the error code returns, unplug the water softener and reconnect any loose wires on the timer. Replace the wire harness if damaged. Replace the timer if the wire harness is okay.
Most common symptoms to help you fix your air compressors
Choose a symptom to see related air compressor repairs.
Main cause: bad check valve...
Main causes: tank drain valve open or leaking air, leaky air tank, bad safety valve, worn pump seals, bad pump valve pla...
Main cause: faulty output air pressure regulator...
Main cause: bad air tank pressure gauge...
Main causes: bad safety valve, pressure switch failure...
Main causes: loose air tube fitting connections, bad check valve, faulty safety valve, damaged or corroded air tank, bad...
Main causes: rusted air tank, loose air tube fitting connections, bad check valve, leaky safety valve, bad tank drain va...
Main causes: lack of electrical power, check valve failure, bad pressure switch...
Most common repair guides to help fix your air compressors
These step-by-step repair guides will help you safely fix what’s broken on your air compressor.
How to replace an air compressor check valve
You can replace a defective air compressor check valve in about 10 minutes....
How to replace an air compressor pressure switch
You can replace a broken air compressor pressure switch in about 45 minutes. ...
How to rebuild an air compressor pump
If the air compressor won't fill the tank with compressed air, rebuild the pump using these steps in about 45 minutes. ...
Effective articles & videos to help repair your air compressors
Use the advice and tips in these articles and videos to get the most out of your air compressor.
Find out how to reduce air compressor noise....
Learn about the possible dangers associated with using an air compressor and how you can reduce the risks of property da...
Learn how to maintain an oil-less air compressor for safe and efficient operation....