Goodman
Heating & Cooling Combined Unit

Model # PGB030100-1 Official Goodman package gas

Here are the diagrams and repair parts for Official Goodman PGB030100-1 package gas, as well as links to manuals and error code tables, if available.

There are a couple of ways to find the part or diagram you need:

  • Click a diagram to see the parts shown on that diagram.
  • In the search box below, enter all or part of the part number or the part’s name.

Not all parts are shown on the diagrams—those parts are labeled NI, for “not illustrated”.

We encourage you to save the model to your profile, so it’s easy to access parts and manuals for your appliance whenever you log in.

For DIY troubleshooting advice and repair guides, visit our repair help section.

Model diagram and schematic

SEARCH WITHIN THIS MODEL

?

This is the number corresponding to the part on the diagram / schematic

Search
ALL PARTS
Showing 10 of 123 parts  |

Air Handler Transformer B1141643
#21

Motor,coil and control diagram

Air handler transformer

Part #B1141643

Replaced by #0130M00138S

?
Manufacturer substitution
This part replaces B1141643. Substitute parts can look different from the original.
This item is not returnable
$50.26
11% OFF Phone Price : $56.26
In Stock
Furnace Inducer Vent Motor Assembly (replaces 20252003, 20460613, B29590-00) B2959000S
#321

Heat exchanger/gas valve/manifold diagram

Furnace inducer vent motor assembly (replaces 20252003, 20460613, b29590-00)

Part #B2959000S

$373.64
$12.00 OFF Phone Price : $385.64
In Stock
Motor 11091205S
#91

Motor,coil and control diagram

Motor

Part #11091205S

Replaced by #B13400312S

?
Manufacturer substitution
This part replaces 11091205S. Substitute parts can look different from the original.
$371.59
$12.00 OFF Phone Price : $383.59
In Stock
Module Dsi PCBAF123S
#151

Motor,coil and control diagram

Module dsi

Part #PCBAF123S

Replaced by #PCBAG123S

?
Manufacturer substitution
This part replaces PCBAF123S. Substitute parts can look different from the original.
$246.64
5% OFF Phone Price : $258.64
In Stock
Bracket, Rollout Switch 2509503

#NI10

All parts diagram

Bracket, rollout switch

Part #2509503

This item is not returnable
In Stock
Box Top 4013007
#411B

Heat exchanger/gas valve/manifold diagram

Box top

Part #4013007

In Stock
Goodman Med Top Panel 2914200S
#551

Cabinet diagram

Goodman med top panel

Part #2914200S

In Stock
Collec Box 2510000S
#331

Heat exchanger/gas valve/manifold diagram

Collec box

Part #2510000S

In Stock
Goodman 10   X 6   Blower Wheel Cw B1368034S
#111

Motor,coil and control diagram

Goodman 10 x 6 blower wheel cw

Part #B1368034S

In Stock
Goodman Gas Access Pnl. W/paint-med 2913300P
#441

Cabinet diagram

Goodman gas access pnl. w/paint-med

Part #2913300P

In Stock

Most common symptoms to help you fix your heating & cooling combined units

Choose a symptom to see related heating and air conditioning system repairs.

Thermostat problem, clogged air filter, burner failure…

Dirty air filter, clogged condenser coils, low refrigerant charge, faulty compressor…

Thermostat problems, bad compressor/condenser fan capacitor, lack of refrigerant, failed compressor…

Dirty flame sensor, failed flame sensor, damaged burner, bad high limit switch…

Main causes: errant thermostat settings, lack of electrical power, clogged drain line, wiring failure, control failure.…

Main causes: Errant thermostat settings, lack of power, bad interlock switches, lack of exhaust ventilation, wiring fail…

Most common repair guides to help fix your heating & cooling combined units

These step-by-step repair guides will help you safely fix what’s broken on your HVAC system.

How to unclog the air conditioner drain line

How to unclog the air conditioner drain line

The condensate drain line for your central air conditioner can clog with mold and mildew. Water will back up and start d…

Repair difficulty
Time required
 15 minutes or less
How to replace the furnace flame sensor

How to replace the furnace flame sensor

The flame sensor detects when furnace burner flames are lit. You may need to replace the flame sensor if flames only sta…

Repair difficulty
Time required
 15 minutes or less
How to replace a heating and air conditioning system thermostat

How to replace a heating and air conditioning system thermostat

The control thermostat for your HVAC system can stop working. This repair guide shows how to replace it.…

Repair difficulty
Time required
 30 minutes or less

Effective articles & videos to help repair your heating & cooling combined units

Use the advice and tips in these articles and videos to get the most out of your HVAC system.

Maintaining your air conditioner

Maintaining your air conditioner

Learn how to maintain your central air conditioner to keep it running smoothly all summer long.…

How to prevent the 2 most common AC failures from ruining your summer

How to prevent the 2 most common AC failures from ruining your summer

Get tips to help keep your central AC running all summer long…

What to check if your air conditioner isn't cooling video

What to check if your air conditioner isn't cooling video

If your central air conditioner isn't cooling as it should, we'll show you how to check for a tripped float switch and c…