LG
Dehumidifier

Model # LHD45ELT8 Official LG dehumidifier

Here are the diagrams and repair parts for Official LG LHD45ELT8 dehumidifier, as well as links to manuals and error code tables, if available.

There are a couple of ways to find the part or diagram you need:

  • Click a diagram to see the parts shown on that diagram.
  • In the search box below, enter all or part of the part number or the part’s name.

Not all parts are shown on the diagrams—those parts are labeled NI, for “not illustrated”.

We encourage you to save the model to your profile, so it’s easy to access parts and manuals for your appliance whenever you log in.

For DIY troubleshooting advice and repair guides, visit our repair help section.

Model diagram and schematic

SEARCH WITHIN THIS MODEL

?

This is the number corresponding to the part on the diagram / schematic

Search
ALL PARTS
Showing 10 of 31 parts  |

Lg Cabinet 3090A10042P
#1400

Exploded view parts diagram

Lg cabinet

Part #3090A10042P

In Stock
Dehumidifier Blower Wheel 5900A20007B
#9012

Exploded view parts diagram

Dehumidifier blower wheel

Part #5900A20007B

This item is not returnable
In Stock
Lg Condenser Assembly ACG65488301
#4030

Exploded view parts diagram

Lg condenser assembly

Part #ACG65488301

In Stock
Caster 4441A30001B
#4410

Exploded view parts diagram

Caster

Part #4441A30001B

Replaced by #MHA62753001

?
Manufacturer substitution
This part replaces 4441A30001B. Substitute parts can look different from the original.
In Stock
Mount 4960A20009B
#9600

Exploded view parts diagram

Mount

Part #4960A20009B

The manufacturer no longer makes this part, and there's no substitute part

Handle 3650A20004B
#6500

Exploded view parts diagram

Handle

Part #3650A20004B

The manufacturer no longer makes this part, and there's no substitute part

Air Filter 5230A20040A
#2302

Exploded view parts diagram

Air filter

Part #5230A20040A

The manufacturer no longer makes this part, and there's no substitute part

Capillary Tube Assembly AJR36701301
#2111

Exploded view parts diagram

Capillary tube assembly

Part #AJR36701301

The manufacturer no longer makes this part, and there's no substitute part

Connect Hose 5214A20027B
#2140

Exploded view parts diagram

Connect hose

Part #5214A20027B

The manufacturer no longer makes this part, and there's no substitute part

Discharge Tube Assembly AJR36701402
#2113

Exploded view parts diagram

Discharge tube assembly

Part #AJR36701402

The manufacturer no longer makes this part, and there's no substitute part

Most common symptoms to help you fix your dehumidifiers

Choose a symptom to see related dehumidifier repairs.

Main causes: dirty air filter, clogged grill, dehumidifier placed too close to the wall, dehumidifier too small for the ...

Main causes: lack of electrical power, wiring failure, electronic control board failure, user interface control failure...

Main causes: dehumidifier too small for the space, bad humidity sensor, faulty evaporator thermistor, low refrigerant, b...

Main causes: weak or dead batteries, out of range, radio frequency interference...

Main causes: room temperature below 65 degrees Fahrenheit, control system failure...

Main causes: clogged drain hose, drain hose not properly connected...

Main causes: loose fan motor mounting screws, loose compressor mounting bracket screws, bad fan, faulty compressor...

Main causes: collection bucket not installed, collection bucket full of water...

Main causes: collection bucket not installed correctly, cracked collection bucket, loose drain hose connection...

Most common repair guides to help fix your dehumidifiers

These step-by-step repair guides will help you safely fix what’s broken on your dehumidifier.

How to replace a dehumidifier electronic control board

How to replace a dehumidifier electronic control board

If the dehumidifier won’t power up because the control board has failed, use the steps in this repair guide to replace t...

Repair difficulty
Time required
45 minutes or less
How to replace a dehumidifier user interface control board

How to replace a dehumidifier user interface control board

If the dehumidifier doesn’t respond when you try to set it, follow these steps to replace it....

Repair difficulty
Time required
30 minutes or less
How to replace a dehumidifier sensor assembly

How to replace a dehumidifier sensor assembly

If the humidifier sensor doesn’t properly detect humidity or evaporator temperature, install a new sensor assembly, foll...

Repair difficulty
Time required
45 minutes or less

Effective articles & videos to help repair your dehumidifiers

Use the advice and tips in these articles to get the most out of your dehumidifier.

How to repair broken or damaged wires video

How to repair broken or damaged wires video

Learn how to repair broken, frayed or damaged wires in your appliances....

How to use a multimeter to test electrical parts video

How to use a multimeter to test electrical parts video

Learn how to use a multimeter to check for wiring problems in an appliance that's not working...

How does a dehumidifier work?

How does a dehumidifier work?

Discover how a dehumidifier works....